Maximizing the Absorbed Power of A Point Absorber Using An FA-Based Optimized Model Predictive Control

在线阅读 下载PDF 导出详情
摘要 Thispaperpresentsanextendedmodelpredictivecontrollerformaximizingtheabsorbedpowerofapointabsorberwaveenergyconverter.Owingtothegreatinfluenceofcontrollerparametersupontheabsorbedpower,theoptimizationoftheseparametersiscarriedoutforthefirsttimebyafireflyalgorithm(FA).Error,thedifferencebetweenoutputvelocityofbuoyandinputwavespeedwhichleadstopowermaximizationintheoptimizedMPCiscomparedwiththeclassicalMPC.Simulationresultsindicatethatgiventhehighaccuracyandacceptablespeedofthealgorithm,itcanadjusttheparametersofthecontrollertothepointwheresystemerrordecreasedeffectivelyandtheabsorbedenergyincreasedabout4MW.
机构地区 不详
出版日期 2018年06月16日(中国期刊网平台首次上网日期,不代表论文的发表时间)